Intrinsic Safety Barriers & Modules connect hazardous-area field devices to industrial control systems through energy-limiting, signal isolation, and intrinsically safe I/O interfacing. This category includes Allen-Bradley Bulletin 937Z zener barriers, Bulletin 937T isolator barriers, and 1718 Ex I/O for applications that require grounded barrier designs, galvanic isolation, or distributed intrinsically safe I/O in chemical, petrochemical, and oil and gas environments.
Intrinsic Safety Barriers & Modules connect hazardous-area field devices to industrial control systems through energy-limiting, signal isolation, and intrinsically safe I/O interfacing. This category includes Allen-Bradley Bulletin 937Z zener barriers, Bulletin 937T isolator barriers, and 1718 Ex I/O for applications that require grounded barrier designs, galvanic isolation, or distributed intrinsically safe I/O in chemical, petrochemical, and oil and gas environments.
Intrinsic Safety Barriers & Modules connect hazardous-area field devices to industrial control systems through energy-limiting, signal isolation, and intrinsically safe I/O interfacing. This category includes Allen-Bradley Bulletin 937Z zener barriers, Bulletin 937T isolator barriers, and 1718 Ex I/O for applications that require grounded barrier designs, galvanic isolation, or distributed intrinsically safe I/O in chemical, petrochemical, and oil and gas environments.
Intrinsic safety barriers and modules for hazardous area signal interfacing
Intrinsic safety barriers and modules are used to interface sensors, transmitters, switches, and other field devices installed in hazardous locations with the control system in the safe area. In this category, Allen-Bradley offerings include Bulletin 937Z zener barriers, Bulletin 937T isolator barriers, and 1718 Ex I/O modules for projects that need intrinsic safety signal protection, galvanic isolation, or distributed intrinsically safe I/O architecture.
Compare intrinsic safety solutions in this category
-
937Z zener barriers are typically used when a grounded barrier approach is acceptable. These modules use Zener diodes to limit energy transferred into the hazardous area and are often considered for compact analog and discrete instrument loops. Rockwell literature identifies options such as slim DIN rail designs, one- and two-channel versions, diode return models, and high-power versions with lower serial resistance for higher field-device voltage.
-
937T isolator barriers are generally selected when galvanic isolation is preferred or when grounding strategy is a major design consideration. Depending on model, these isolator barriers may provide diagnostic and configuration features such as line fault detection, power rail options, and setup by DIP switches or Field Device Tool software.
-
1718 Ex I/O modules support a more distributed intrinsically safe I/O approach closer to the field. Rockwell positions the 1718 platform for EtherNet/IP integration and compact chassis-based deployment, and analog modules are identified with standard HART 7 support. Exact installation conditions depend on the certified system design, enclosure, and selected modules.
How to choose between zener barriers, isolator barriers, and Ex I/O
The best fit depends on signal type, loop design, panel layout, maintenance priorities, and how the hazardous-area interface should connect into the larger automation architecture. Zener barriers are often chosen for straightforward grounded-loop protection. Isolator barriers are commonly preferred where galvanic isolation, simplified grounding practice, or additional diagnostics matter more. 1718 Ex I/O is typically evaluated when the application benefits from distributed intrinsically safe I/O over EtherNet/IP rather than traditional point-to-point barrier marshalling.
Key selection factors when shopping this category
-
Signal type: review whether the application involves analog transmitters, discrete inputs, discrete outputs, or mixed signal requirements.
-
Channel count and density: compare single-channel and multi-channel options based on cabinet space and loop count.
-
Grounding method: zener barriers are typically considered where a grounded barrier design is acceptable, while isolator barriers are often preferred when direct grounding constraints are less desirable.
-
Isolation needs: evaluate whether galvanic isolation is required between the field device and control system.
-
Diagnostics and maintenance: depending on model, line fault detection, configuration features, and other diagnostics may support troubleshooting and lifecycle maintenance.
-
HART and network integration: review whether HART support or EtherNet/IP-based distributed I/O architecture is needed for the project.
Applications for intrinsic safety barriers and modules
These products are commonly applied in chemical, petrochemical, and oil and gas facilities where hazardous-area instrumentation must connect reliably to monitoring and control systems. For OEMs, system integrators, panel builders, and plant engineers, this category supports selection by loop type, grounding approach, isolation method, diagnostics, and distributed I/O architecture without extending beyond the Allen-Bradley 937Z, 937T, and 1718 Ex I/O families included here.