Chassis-based PLC communication modules in this category are specifically designed for Allen-Bradley ControlLogix 1756 systems. These in-chassis network interface modules install directly into a 1756 rack and are used to connect the ControlLogix platform to plant, machine, and legacy industrial networks such as EtherNet/IP, ControlNet, DeviceNet, DH+, remote I/O, and SynchLink. They are commonly sourced for new rack builds, replacement of failed communication interfaces, chassis expansion, and migration projects that must maintain connectivity with existing Allen-Bradley network architectures. This category covers 1756 chassis-installed communication modules only and does not include standalone gateways, accessories, or non-chassis networking products.
ControlLogix AC входен модул, 16 входа, 8 точки на група, 120V AC, работен диапазон 74…132V AC, софтуерно конфигурируема промяна на състоянието, конформно покритие
Жизнен цикъл: Unknown
Chassis-based PLC communication modules in this category are specifically designed for Allen-Bradley ControlLogix 1756 systems. These in-chassis network interface modules install directly into a 1756 rack and are used to connect the ControlLogix platform to plant, machine, and legacy industrial networks such as EtherNet/IP, ControlNet, DeviceNet, DH+, remote I/O, and SynchLink. They are commonly sourced for new rack builds, replacement of failed communication interfaces, chassis expansion, and migration projects that must maintain connectivity with existing Allen-Bradley network architectures. This category covers 1756 chassis-installed communication modules only and does not include standalone gateways, accessories, or non-chassis networking products.
AC Input Module Allen-Bradley ControlLogix 1756-IA16K
ControlLogix AC Input Module, 16 Inputs, 8 Points per Group, 120V AC, 74…132V AC Operating Range, Software-Configurable Change of State, Conformally Coated
ControlLogix AC Input Module, 16 Inputs, 8 Points per Group, 120V AC, 74…132V AC Operating Range, Software-Configurable Change of State, Conformally Coated
ControlLogix AC входен модул, 16 входа, 8 точки на група, 120V AC, работен диапазон 74…132V AC, софтуерно конфигурируема промяна на състоянието, конформно покритие
Жизнен цикъл: Unknown
Adapter Allen-Bradley ControlLogix 1756-PSCA2K
ControlLogix redundant power supply chassis adapter, 4 A at 3.3V DC, 15 A at 5.1V DC, 2.8 A at 24V DC, 0 to 60 °C operating temperature
Lifecycle Status: Active
ControlLogix redundant power supply chassis adapter, 4 A at 3.3V DC, 15 A at 5.1V DC, 2.8 A at 24V DC, 0 to 60 °C operating temperature
Lifecycle Status: Active
ControlLogix адаптер за резервирано захранване на шаси, 4 A при 3.3V DC, 15 A при 5.1V DC, 2.8 A при 24V DC, работна температура 0 до 60 °C
Жизнен цикъл: Active
Analog Combo I/O Module Allen-Bradley ControlLogix 1756-IF4FXOF2FK
ControlLogix analog combo I/O module, 6 channels, +/-10V and 0-21 mA input, +/-10.4V and 0-21 mA output, conformal coating
Lifecycle Status: Active
ControlLogix analog combo I/O module, 6 channels, +/-10V and 0-21 mA input, +/-10.4V and 0-21 mA output, conformal coating
Lifecycle Status: Active
ControlLogix аналогов комбиниран I/O модул, 6 канала, входове +/-10 V и 0-21 mA, изходи +/-10.4 V и 0-21 mA, конформно покритие
Жизнен цикъл: Active
Analog I/O Module Allen-Bradley ControlLogix 1756-IF4FXOF2F
ControlLogix analog combination I/O module, 4 high-speed differential analog inputs, 2 high-speed analog outputs, ±10 V and 0…20 mA ranges, 300 µs minimum scan time, 1 ms minimum RPI
Lifecycle Status: Active
ControlLogix analog combination I/O module, 4 high-speed differential analog inputs, 2 high-speed analog outputs, ±10 V and 0…20 mA ranges, 300 µs minimum scan time, 1 ms minimum RPI
Lifecycle Status: Active
ControlLogix аналогов комбиниран I/O модул, 4 високоскоростни диференциални аналогови входа, 2 високоскоростни аналогови изхода, диапазони ±10 V и 0…20 mA, минимално време за сканиране 300 µs, минимален RPI 1 ms
Жизнен цикъл: Active
Analog Input Module Allen-Bradley ControlLogix 1756-IF16
ControlLogix analog input module, 16-point A/I, input signal 0-10.25V, +/-10.25V, 0-5.125V, 0-20.5mA, 250V continuous reinforced isolation inputs-to-backplane, module health/in calibration/mode display
Lifecycle Status: Active
ControlLogix analog input module, 16-point A/I, input signal 0-10.25V, +/-10.25V, 0-5.125V, 0-20.5mA, 250V continuous reinforced isolation inputs-to-backplane, module health/in calibration/mode display
Lifecycle Status: Active
ControlLogix аналогов входен модул, 16 аналогови входа, входни сигнали 0-10.25V, +/-10.25V, 0-5.125V, 0-20.5mA, 250V непрекъсната усилена изолация входове-към-backplane, индикация Module Health / In Calibration / Mode
Жизнен цикъл: Active
Analog Input Module Allen-Bradley ControlLogix 1756-IF16H
ControlLogix analog input module, 16-point HART analog input, 0…20 mA or 4…20 mA input ranges, real-time sampling, wire-off detection
Lifecycle Status: Active
ControlLogix analog input module, 16-point HART analog input, 0…20 mA or 4…20 mA input ranges, real-time sampling, wire-off detection
Lifecycle Status: Active
ControlLogix аналогов входен модул, 16-канален HART аналогов вход, входни диапазони 0…20 mA или 4…20 mA, семплиране в реално време, детекция за прекъснат проводник
Жизнен цикъл: Active
Analog Input Module Allen-Bradley ControlLogix 1756-IF16IHK
ControlLogix analog input module, 16 channels, 0-20 mA and 4-20 mA input, 4-20 mA output, HART support, conformal coating, 250V continuous reinforced isolation
Lifecycle Status: Active
ControlLogix analog input module, 16 channels, 0-20 mA and 4-20 mA input, 4-20 mA output, HART support, conformal coating, 250V continuous reinforced isolation
Lifecycle Status: Active
ControlLogix аналогов входен модул, 16 канала, вход 0-20 mA и 4-20 mA, изход 4-20 mA, HART поддръжка, конформно покритие, 250 V непрекъсната усилена изолация
Жизнен цикъл: Active
Analog Input Module Allen-Bradley ControlLogix 1756-IF8
ControlLogix analog input module, 8-point A/I, input signal 0-10.25V, +/-10.25V, 0-5.125V, 0-20.5mA, 250V continuous reinforced isolation inputs-to-backplane
Lifecycle Status: Active
ControlLogix analog input module, 8-point A/I, input signal 0-10.25V, +/-10.25V, 0-5.125V, 0-20.5mA, 250V continuous reinforced isolation inputs-to-backplane
Lifecycle Status: Active
ControlLogix аналогов входен модул, 8 аналогови входа, входен сигнал 0-10.25V, +/-10.25V, 0-5.125V, 0-20.5mA, 250V непрекъсната усилена изолация между входовете и backplane
Жизнен цикъл: Active
Analog Input Module Allen-Bradley ControlLogix 1756-IF8H
ControlLogix analog input module, 8-point A/I, HART protocol support, +/-10V and 0-20 mA / 4-20 mA input ranges, 50 V continuous channel isolation, module health and calibration display
Lifecycle Status: Active
ControlLogix analog input module, 8-point A/I, HART protocol support, +/-10V and 0-20 mA / 4-20 mA input ranges, 50 V continuous channel isolation, module health and calibration display
Lifecycle Status: Active
ControlLogix аналогов входен модул, 8 аналогови входа, поддръжка на HART, входни диапазони +/-10 V и 0-20 mA / 4-20 mA, 50 V постоянна изолация между каналите
Жизнен цикъл: Active
Analog Input Module Allen-Bradley ControlLogix 1756-IF8I
ControlLogix analog input module, 8 isolated inputs, voltage/current configurable, 24-bit resolution, IEEE 32-bit floating point, 1 ms min scan time
Lifecycle Status: Active
ControlLogix analog input module, 8 isolated inputs, voltage/current configurable, 24-bit resolution, IEEE 32-bit floating point, 1 ms min scan time
Lifecycle Status: Active
ControlLogix аналогов входен модул, 8 изолирани входа, конфигурируеми по напрежение/ток, 24-битова резолюция, IEEE 32-bit floating point, мин. време за сканиране 1 ms
Жизнен цикъл: Active
Analog Input Module Allen-Bradley ControlLogix 1756-IF8IH
ControlLogix analog input module, 8 isolated current inputs, HART protocol support, 24-bit Sigma-Delta ADC, 32-bit floating point data, 0...20 mA and 4...20 mA configurable input ranges
Lifecycle Status: Active
ControlLogix analog input module, 8 isolated current inputs, HART protocol support, 24-bit Sigma-Delta ADC, 32-bit floating point data, 0...20 mA and 4...20 mA configurable input ranges
Lifecycle Status: Active
ControlLogix аналогов входен модул, 8 изолирани токови входа, HART протокол, 24-битов Sigma-Delta ADC, 32-битов floating point формат на данните, конфигурируеми диапазони 0...20 mA и 4...20 mA
Жизнен цикъл: Active
Analog Input Module Allen-Bradley ControlLogix 1756-IF8IHK
ControlLogix analog input module, 8 channels, 0-20 mA and 4-20 mA input, 4-20 mA output, HART protocol, 250V continuous reinforced isolation, conformal coating
Lifecycle Status: Active
ControlLogix analog input module, 8 channels, 0-20 mA and 4-20 mA input, 4-20 mA output, HART protocol, 250V continuous reinforced isolation, conformal coating
Lifecycle Status: Active
ControlLogix аналогов входен модул, 8 канала, вход 0-20 mA и 4-20 mA, изход 4-20 mA, HART протокол, 250 V непрекъсната усилена изолация, конформно покритие
Жизнен цикъл: Active
Chassis-Based Communication Modules for ControlLogix 1756 Racks
These PLC communication modules are chassis-installed network interface modules for Allen-Bradley ControlLogix 1756 platforms. Mounted directly in a 1756 chassis slot, they provide the communication link between the controller platform and external networks, connected I/O, other controllers, engineering workstations, and installed plant infrastructure. Buyers typically source these modules when configuring a new ControlLogix rack, replacing a failed in-chassis communication card, expanding an existing chassis, or supporting a phased upgrade from older Allen-Bradley systems.
Supported Network Types
This category includes 1756 communication modules used across several common ControlLogix network environments.
-
EtherNet/IP modules support Ethernet-based communication for controller messaging, I/O exchange, and broader plant network integration.
-
ControlNet modules are used in ControlLogix systems built around scheduled and repeatable network communication.
-
DeviceNet modules connect the chassis to existing DeviceNet devices and device-level networks.
-
DH+ and remote I/O modules are typically selected for legacy system communication, retrofit work, and migration from older Allen-Bradley architectures.
-
SynchLink modules are used in specialized coordinated drive and synchronized data-sharing applications.
How Buyers Typically Select the Right Module
The main selection factor is the required network. From there, buyers usually confirm whether the module is being purchased for a new installation, a direct replacement, a rack expansion, or a legacy integration project. In many facilities, the correct 1756 communication module is determined by the network already used by the controller, remote I/O layout, plant infrastructure, or existing migration plan.
-
Choose EtherNet/IP modules for Ethernet-based ControlLogix communication and network connectivity.
-
Choose ControlNet modules for systems designed around ControlNet communication.
-
Choose DeviceNet modules when the chassis must interface with installed DeviceNet devices.
-
Choose DH+ or remote I/O modules when maintaining or integrating legacy Allen-Bradley networks.
-
Choose SynchLink modules for specialized synchronized motion or coordinated drive architectures.
Common Purchasing and Retrofit Use Cases
ControlLogix chassis-based communication modules are often purchased for maintenance spares, failed card replacement, machine rebuilds, brownfield upgrades, and staged modernization projects where older networks remain in service. For OEMs, integrators, and MRO buyers, the key purchasing considerations are chassis-based installation, network compatibility, legacy support requirements, and the role the module must perform within the 1756 platform.
This page is limited to chassis-based 1756 communication modules for ControlLogix systems and is intended for buyers sourcing in-rack network connectivity modules rather than standalone gateways or communication accessories.